Lumistar Luminaire USL 06-Ex, aluminium

Luminaires (Ex)

Product Picture: Lumistar Luminaire USL 06-Ex, aluminium
  • ex II 2G Ex d (e), IIC T3/T4 Gb
  • ex II 2D Ex tb IIIC T195°C/T130°C/T120°C/T80°C Db

Suitable for Explosion hazardous areas

Temperature Class: to T4(depending on power rating)
Ambient temperature: up to 60°C II C (all explosion classes)

Suits Lumiglas Sight Glass Fitting, circular DIN 28120/28121 or similar from size DN 50 and Lumiglas Screwed Sight Glass Fitting MV from DN 65 to DN100

Operating voltage: 12V, 24V, 120V, 230V, 240V
Power, depending on voltage: up to 50W

Electric connection:

Version I: resin cast gland/cable tail,

Version II: terminal box and cable gland

Secured by hinged bracket or adapter flange

Please note that the halogen bulb 230 V – 75 Watt is no longer available.

Downloads

Lumistar Timer (internal) – Integral Time Delay switch for Lumiglas Luminaires

Luminaires (Ex)

Product Picture: Lumistar Timer (internal)

The integrally fitted Lumistar timer enables the unit to be switched on directly or indirectly. After a preprogrammed interval (appx. 5 minutes) the luminaire is automatically switched off.

Application: For better utilisation of the operating life of the halogen filament lamp, and particularly useful where visual inspection procedures is only passing and brief illumination of vessel internals is required. Also saves power and keeps temperature down.

The Lumistar timer is so compact that it will fit into almost all more sized  Lumistar luminaires:

Lumistar luminaires for Non-Ex hazardous areas:

– Lumistar luminaires type Lumistar, size 175 to 225
– Lumistar luminaires type USL, beginning from USL 06

Lumistar luminaires for Ex hazardous areas:

– Lumistar luminaires type USL, beginning from USL 06-Ex
– Lumistar light guide luminaire USL 07 LF-ExLumiflex

Protection: corresponds to luminaire specification 
Fitting and function: The Lumistar timer is either fitted or can be  retrospectively fitted at manufacturer`s works into the relevant Lumistar luminaire.

Two alternative operating functions can be used:
Once voltage is applied to the luminaire, the timed lighting starts automatically and runs for a period of around five minutes.
1. Remote control
If the applied voltage is momentarily interrupted (for about 1 or 2 seconds), for instance by pressing a pushbutton (break contact), the automatical process is restarted.
2. Direct control
The automatical process is restarted by a spring-loaded lever or a pushbutton located on the outside of the Lumiglas luminaire housing (depending on the version).
Operating voltage: 12 V, 24 V, 120 V, 230 V
Power: max. 50 W (12 V) max. 100 W (24 V, 120 V, 230 V)

Overview:

Integral Time Delay swith for Lumiglas Luminaires
For Series USL 06/07 Ex, ESL 26 Ex or non Ex
With a programmed time delay of approximately 5 minutes

Downloads