Lumistar Luminaire USL08LED-Ex-UL

Lumistar Luminaire USL08LED-Ex, UL-listed + T6

 

  • UL-listed
  • Temperature class T6 at a Ambient temperature up to 50°C
  • Extended voltage range (120 – 240 V AC)
  • Subsequent change of the radiation angle possible
    (15°, 25°, 35°)
  • LED technology with more efficient light output
    compared to the halogen version
  • Can be exchanged for the old halogen version 1:1, as the housing and the fixings have not changed on the outside

The Lumistar USL08 with UL/cUL Ex-listed is now also available in LED technology and can be are manufactured and sold. The approval includes the following technical details:

Voltage range: 120-240V
Approved for: − Class I Div. 1 and 2, Groups C and D, temperature class T6 at max. ambient temperature 50°C
− Class I Div. 2 Groups A, B, C, D, temperature class T2

There are two versions with different radiation angles and light colours:

Version 1:

  • Lumistar USL08LED-Ex with LED chip. (COB Version à Chip on Board)
  • Light output max. 2200 lumen
  • With this version, a subsequent lens change by the customer is possible. (possible radiation angles 15°,25°,35°)


Part no :
LS#3542.501.00 incl. 15° lens
LS#3542.502.00 incl. 25° lens
LS#3542.503.00 incl. 35° lens
Version 2:
Lumistar USL08LED-Ex with the 7-gang LED card from the Lumistar luminaires USL07LED or ESL/ ASL55 LED
Light output max. 1600 lumen (for applications where too high light output can cause glare,  e.g : (small boilers)
Part no :
LS#3542.504.00 incl. 11° lens
LS#3542.505.00 incl. 26° lens
Available: immediately
Delivery time: 2-3 weeks
Price (net): Euro 725,00
Attachment: Data Sheet

Lumistar Luminaires USL 06, aluminium

Luminaires (Non-Ex)

Product Picture: Lumistar Luminaires USL 06, aluminium

Also available in LED technology

Fully Sealed Lumistar Sight Glass Luminaire with cover glass

Suits Lumiglas Sight Glass Fitting, circular DIN 28120/28121 or similar from size DN 50 and Lumiglas Screwed Sight Glass Fitting MV from DN 65 to DN 100

Operating voltage: 12 V, 24 V, 120 V, 230 V
Power, dependant on operating voltage, up to 100 W
Secured by hinged bracket or adapter flange

Please note that the halogen bulb 230 V – 75 Watt is no longer available.

Downloads

Lumistar Luminaire ASL 57-LED, aluminium

Luminaires (Non-Ex)

Product Picture: Lumistar Luminaire ASL 57-LED, aluminium

This sight glass luminaire is designed for universal applications and is ideal for use in combined sight and light ports (single-flanged version) or with two separate ports (2-flange version).

Applications:

For illuminating visual flow indicators, pipelines, laboratory mixers, bio-reactors as well as the interior of tanks, hoppers, silos, agitators and other, normally closed, vessels and reactors in non-explosive environments.

The specific advantages of Lumiglas LED technology:

  • Insensitive to vibration
  • Long service life and high operational reliability
  • Continuous operation for LED up to about 50,000 hours
  • The ideal solution wherever fittings are difficult to access
  • No heat radiation in the light port (cold light)
  • No additional heat which would be undesirable for chemical and/or biological processes
  • Extreme high-contrast lighting

Protection class: IP 65

Operating voltage: 24 V AC/DC 35 W; 120-230 V AC 35 W, equipped with one high-power LED
Voltage type: AC/DC

Fastening options: Luminaires for sight glasses on circular fittings and visual flow indicators are mounted on the cover flange using the hinged bracket.  With the screw-type sight glass fitting acc. to DIN 11851 or similar, the luminaire is fastened with a flange collar or direct on the slotted nut.

Downloads

Lumiglas Tubular Sight Glass/Flow Indicator

Flanged at both ends DIN 2642 mating sizes PN 10 for fitting into pipelines

Length over flange: DIN 3202 F1

Application:
For visual control of state of fluid and flow in pipelines

Sizes from DN10 to DN200, also available with ANSI flanges
Stainless steel 1.4571(316Ti) flanges or other on request
Metal-(1.4301) or Plexi-glass outer shell for extra protection on request

Operating conditions:
Operating pressure: up to 6 bar, depending on wall thickness (higher ratings on request)

Operating temperature: up to 220°C

Materials of components referred to in adjoining exploded view (within data  sheet below):
Item Part Material
1 Connecting flange Stainless steel 1.4571 or other
2 Glass cylinder Borosilicate glass (DURAN)
3 Ring seals Silicon rubber or other
4 Spacer bars Stainless steel 1.4301 or other
5 Securing bolts A 2 or other
(with spring washer)

Special versions:
– with stainless steel or protective Plexiglas outer shell
– ANSI flanges
– customized length

Installation:
– The flow indicator is bolted, using suitable gaskets, directly between the mating flanges of the pipeline.
– The flow indicator should be fitted so that no stresses (tensile, compression or torsional) are caused on tightening up.

Ordering information:
e. g. Lumiglas tubular sightglass/flow indicator DN 100, material 1.4571, borosilicate glass, 6 bar operating pressure,
length over flanges 350

product photo: Lumiglas Tubular Sight Glass/Flow Indicator

Downloads