Lumistar Luminaire SLM, aluminium

Product Picture: Lumistar Luminaire SLM, aluminium

also available in LED technology

A version of the ‘Lumistar’ adapted for use with Lumiglas Screwed Sight Glass Fitting MV

Nominal dia: DN 65 to DN 125
Operating voltage: 24V AC/DC
Power, depending on size: 20W, 50W or 100W
Luminaire is fastened to branch nozzle by slotted cover nut
Standard product with momentary push button
Model in stainless steel available, refer to Lumistar Luminaire ‘ME’

Downloads

Lumistar Luminaire USL 05, aluminium

Product Picture: Lumistar Luminaire USL 05, aluminium

Also available in LED technology

Fully Sealed Lumistar Sight Glass Luminaire with cover glass
Compact yet powerful light

Suits Lumiglas Sight Glass Fitting, circular DIN 28120/28121 or similar from size DN 40 and Lumiglas Screwed Sight Glass Fitting MV from DN 65

Operating voltage/power: 24V / 20W or 50W (without internal transformer) 120V / 230W, 12V / 5W (with internal transformer)
Secured by hinged bracket or adapter flange

Downloads

Lumistar Luminaires USL 06, aluminium

Luminaires (Non-Ex)

Product Picture: Lumistar Luminaires USL 06, aluminium

Also available in LED technology

Fully Sealed Lumistar Sight Glass Luminaire with cover glass

Suits Lumiglas Sight Glass Fitting, circular DIN 28120/28121 or similar from size DN 50 and Lumiglas Screwed Sight Glass Fitting MV from DN 65 to DN 100

Operating voltage: 12 V, 24 V, 120 V, 230 V
Power, dependant on operating voltage, up to 100 W
Secured by hinged bracket or adapter flange

Please note that the halogen bulb 230 V – 75 Watt is no longer available.

Downloads

Lumiglas Luminaire Lumistar 225-LED, aluminium

Luminaires (Non-Ex)

Product Picture: Lumiglas Luminaire Lumistar 225-LED, aluminium

Lumiglas Luminaire Lumistar 225-LED  is suitable for combining as sight glass and light glass; can be installed on circular sight port fittings acc. to DIN 28120 DN 200

Application:

For illuminating the interiors of vessels and tanks, hoppers, silos, stirring plant and similar, usually enclosed, containers in facilities where there is no potentially explosive environment.

The special advantages of Lumiglas LED technology:

  • Resistant to vibrations
  • Long service life and high operating safety
  • Service life: Up to 50,000 hours
  •  Optimal for fittings that are difficult to access
  • No heat radiation in light beam (cold light)
  • No additional heat which would be undesirable for chemical and/or biological processes.
  • High-definition illumination

Type of protection: Dust- and water-jet-tight if properly installed, IP 65 acc. to EN 60529/DIN VDE 0470 Part 1

Electrical data:
– Operating voltage AC/DC: alternative 12 V; 24-48 V; 120-230 V
– Lamp: 2 x 3 high-power LED
– Power: ca. 22 W
– Push-button operation possible

Downloads

Lumistar Luminaire ASL 55-LED, aluminium

Luminaires (Non-Ex)

Product Picture: Lumistar Luminaire ASL 55-LED, aluminium

Lumistar Luminaires ASL 55-LED (aluminium) and ESL 55-LED (stainless steel)

Sight glass luminaire for universal applications; ideally suited for sight glass and light port combinations (single-flange version) and for separate  configurations (double-flange version).

Applications:

The optimum solution in the pharmaceutical and food processing industries, ideal for illuminating bioreactors, laboratory mixers and filters as well as the interiors of boilers, tanks, agitators, separators, pipes and other – usually sealed – vessels in operating environments that are not potentially explosive.

The specific advantages of Lumiglas LED technology:

  • Insensitive to vibration
  • Long service life and high operational reliability
  • Continuous operation for LED up to about 50,000 hours
  • The ideal solution wherever fittings are difficult to access
  • No heat radiation in the light port (cold light)
  • No additional heat which would be undesirable for chemical and/or biological processes
  • Extreme high-contrast lighting

Compact yet powerful:

Dazzle-free illumination; suitable for use with circular sight glass fittings to DIN28120/DIN28121 or similar, with screw-type sight glass fittings in compliance with DIN 11851, and in sight flow indicators.

Type of protection: Dust-tight and waterjet-proof, IP 65 acc. to EN 60529/
DIN VDE 0470, Part 1

Electrical data:

Convenient electrical link-up: The Lumistar luminaire is equipped with a factory-mounted screwed cable gland.

The Lumistar luminaire ASL-/ESL 55-LED is compatible with the following nominal diameters:
a) Circular sight glass fitting acc. to DIN 28120: DN 40
b) Circular sight glass fitting acc. to DIN 38121: DN 40
c) Sight glasses in flow indicators: DN 50
d) Screw-type sight glass fittings similar to DIN 11851:
DN 50 is mounted by way of a separate flange attachment
– From DN 80 up, the unit is secured using the hinged bracket

Lumistar luminaires ASL 55-LED and ESL 55-LED have a special adapter in the light port as a standard feature, making this type of lamp ideal for applications in aseptic and sterile environments. Excellent results are assured by using sight glasses fused to a metal frame (METAGLAS®) and with the BioControl (NEUMO) range of products. METAGLAS® combines optimally with clamp fittings (METACLAMP®) as well as with NA-ConnectTM technology.

Downloads

Lumistar Luminaire ASL 57-LED, aluminium

Luminaires (Non-Ex)

Product Picture: Lumistar Luminaire ASL 57-LED, aluminium

This sight glass luminaire is designed for universal applications and is ideal for use in combined sight and light ports (single-flanged version) or with two separate ports (2-flange version).

Applications:

For illuminating visual flow indicators, pipelines, laboratory mixers, bio-reactors as well as the interior of tanks, hoppers, silos, agitators and other, normally closed, vessels and reactors in non-explosive environments.

The specific advantages of Lumiglas LED technology:

  • Insensitive to vibration
  • Long service life and high operational reliability
  • Continuous operation for LED up to about 50,000 hours
  • The ideal solution wherever fittings are difficult to access
  • No heat radiation in the light port (cold light)
  • No additional heat which would be undesirable for chemical and/or biological processes
  • Extreme high-contrast lighting

Protection class: IP 65

Operating voltage: 24 V AC/DC 35 W; 120-230 V AC 35 W, equipped with one high-power LED
Voltage type: AC/DC

Fastening options: Luminaires for sight glasses on circular fittings and visual flow indicators are mounted on the cover flange using the hinged bracket.  With the screw-type sight glass fitting acc. to DIN 11851 or similar, the luminaire is fastened with a flange collar or direct on the slotted nut.

Downloads

ATEX: VISULEX Ex-Camera Type K07-Ex, aluminium

VISULEX Camera Systems (Ex)

Product Picture: ATEX: VISULEX Ex-Camera Type K07-Ex, aluminium

  • Ex II 2G Ex de IIC T6 Gb
  • Ex II 2G Ex tb IIIC T80°C Db

Camera with zoom lens. The zoom lens of this camera model is operated remotely from the plant control room. The observer can therefore adjust the setting to suit his individual needs. The LumiCam system and control software package, developed by Lumiglas VISULEX offers a number of real advantages in this respect.

Downloads

Similar to the internationally renowned Lumiglas luminaires, the camera system can be attached to the cover flange of a sight glass fitting using a hinged bracket. If the standard illumination of the process is not sufficient, an additional Lumiglas luminaire can be attached if fitting allows.

Application check list

Please make use of our system conformity for your application of the VISULEX-Lumiglas-camera system so that we are able to submit a correct offer fitting your specific application.

Lumistar Luminaire USL 05-Ex, USL 05-Ex-LED, aluminium

Product Picture: Lumistar Luminaire USL 05-Ex, USL 05-Ex-LED, aluminium
  • ex II 2G Ex d IIC T3/T4/T6/120°C Gb
  • ex II 2D Ex tb IIIC T80/T120/T130/T195°C Db

Suitable for Explosion hazardous areas: Temperature Class: to T6 (depending on power rating)
Ambient temperature: up to 60°C

Suits Lumiglas Sight Glass Fitting, circular DIN 28120/28121 or similar from size DN 40 and Lumiglas Screwed Sight Glass Fitting MV from DN 65

Operating voltage: 12V, 24V, 120V, 230V
Power, depending on voltage: up to 20W
Secured by hinged bracket or adapter flange

Downloads

Lumistar Luminaire USL 06-Ex, aluminium

Luminaires (Ex)

Product Picture: Lumistar Luminaire USL 06-Ex, aluminium
  • ex II 2G Ex d (e), IIC T3/T4 Gb
  • ex II 2D Ex tb IIIC T195°C/T130°C/T120°C/T80°C Db

Suitable for Explosion hazardous areas

Temperature Class: to T4(depending on power rating)
Ambient temperature: up to 60°C II C (all explosion classes)

Suits Lumiglas Sight Glass Fitting, circular DIN 28120/28121 or similar from size DN 50 and Lumiglas Screwed Sight Glass Fitting MV from DN 65 to DN100

Operating voltage: 12V, 24V, 120V, 230V, 240V
Power, depending on voltage: up to 50W

Electric connection:

Version I: resin cast gland/cable tail,

Version II: terminal box and cable gland

Secured by hinged bracket or adapter flange

Please note that the halogen bulb 230 V – 75 Watt is no longer available.

Downloads

Lumistar Luminaire USL 07-Ex, aluminium

Luminaires (Ex)

Product Picture: Lumistar Luminaire USL 07-Ex, aluminium
  • ex II 2G Ex d (e), IIC T3/T4 Gb
  • ex II 2D Ex tb IIIC T195°C/T130°C/T120°C/T80°C Db
  • Suitable for Gas (Zone 1) and Dust (Zone 21) Explosion hazardous areas
  • Temperature Class: to T6 or T80?C(depending on power rating)
  • Ambient temperature: up to 60°C II C (all explosion classes)
  • Suits Lumiglas Sight Glass Fitting, circular DIN 28120/28121 or similar from  size DN 50 and Lumiglas Screwed Sight Glass Fitting MV from DN 100/125

Operating voltage: 12 V, 24 V, 120 V, 230 V, 240 V
Power, depending on voltage: up to 50 W

Electric connection:

Version I: resin cast gland/cable tail,

Version II: terminal box and cable gland

Secured to sight glass flange by twin brackets fastened

This Luminaire has a particularly large light exit and reflector

Please note that the halogen bulb 230 V – 75 Watt is no longer available.

Downloads

Lumistar Luminaire USL 07 LED-Ex, aluminium

Luminaires (Ex)

Product Picture: Lumistar Luminaire USL 07 LED-Ex, aluminium

Ex II 2G Ex db eb IIC T6 Gb
Ex II 2D Ex tb IIIC T80°C Db

This sight glass luminaire is designed for universal applications in potentially explosive operating areas and is ideal either in combined sight and light ports (single-flange version) or for  separate ports (two-flange version).

Application: For illuminating the interiors of vessels, tanks, agitators, silos and other, generally closed, containers and reactors and also in visual flow  indicators in potentially explosive environments. It can be used in virtually any hazardous area and is suitable for food processing.

Small in size and rated EEx d IIC T3…T6 for all explosion classes, the USL07-Ex Luminaire is as versatile as you could ever want.

Compact design, powerful light output:

Glare-free illumination; fits circular sight glass fittings to DIN 28120/DIN 28121 or similar, screw-type sight glass fittings in compliance with DIN 11851, as well as visual flow indicator fittings.

Protection class: Dust-tight and water jet-proof, IP 65 and IP 67 acc. to DIN EN 60529/DIN VDE 0470, part 1 

Voltage type: AC/DC, depending on type of luminaire
Operating voltage:
24 V AC/DC – 14 W
120-230 V AC – 14 W
Beam angle: 11° or 26°

This Luminaire has a particularly large light exit and reflector

Please note that the halogen bulb 230 V – 75 Watt is no longer available.

 

Downloads

Lumistar Luminaire USL 08-Ex; T4A, T3B, aluminium

Luminaires (Ex)

Product Picture: Lumistar Luminaire USL 08-Ex; T4A, T3B, aluminium

Suitable for Explosion hazardous areas

 

Lumistar Luminaire USL 08-Ex, UL-listed + T3B, T4A

 

Safe high-intensity illumination for sight glasses, ports, or general applications in hazardous (classified) locations.

For illuminating the interior of tanks, hoppers, silos, agitators and other, usually closed, vessels and reactors as well as visual flow indicators in potentially explosive environments with UL requirements. Suitable for use in food processing industries.

  • Protection: dust-proof and splash-proof, IP 65 acc. to EN 60 529/ DIN VDE 0470, Part 1
  • Ignition protection, explosion group:
    UL 844 listed for Class I Div. 1 and 2, Groups C and D
    UL 1571 for “wet conditions

Temperature Class: to T4A. Ambient temperature: up to 40°C
Ignition protection: Class 1, Div.1 & 2, Explosion Group: C & D

Suits circular sight glass fittings to DIN 28120/28121 or similar from size DN  50 and screwed sight glass fittings DIN 11851 from DN 100/125

Operating Voltage: 120 V
Power rating: up to 100 W

These sturdy, compact lights are now available in 35 W, 50 W or 100 W  versions.

Secured to sight glass flange by twin brackets fastened

UL-listed
(Ex) Div. I, Div. II

Downloads

 

Lumistar Luminaire ASL 55LED-Ex, aluminium

Luminaires (Ex)

Product Picture: Lumistar Luminaire ASL 55LED-Ex, aluminium

ex II 2G Ex d IIC T6 Gb
ex II 2D Ex tb IIIC T80°C Db

Suitable for Explosion hazardous areas

The Series ASL/ESL55-Ex, an LED luminaire that can be used with a sight  glass in hazardous areas, reducing maintenance costs and allows companies to meet green initiatives. Before now, the only explosion-proof rated luminaires available were very low power, providing little light for viewing. Now companies who want to reduce their carbon footprint can obtain a high-power, Ex-rated LED luminaire that gives operators a well-lit glare-free view of processes through a sight glass. This luminarie is available is made with a 316 stainless steel (Esl 55-LED Ex) housing for harsh environments. Compared to traditional halogen luminaires, the new green-technology LED Lumiglas® luminaires 

The ability to produce light without heat, plus an exceptionally long life make the new green-technology LED Lumiglas® luminaires 

This Ex-type sight glass luminaire is designed for universal applications and is ideal for use in combined sight and light ports (single-flange version) or with two separate ports (2-flange version).

For illuminating visual flow indicators, pipelines, laboratory mixers, bio-reactors as well as the interior of tanks, hoppers, silos, agitators and other, normally closed, vessels and reactors in potentially explosive environments.

The specific advantages of Lumiglas LED technology:

  • vibration-resistant
  • long service life and operational reliability
  • LED functions up to around 50,000 hours in continuous operations
  • optimal for fittings that are difficult to access
  • no heat radiation in the light aperture (cold light)
  • no unwanted additional heat in chemical and/or biological processes
  • extremely high-contrast illumination

Protection class: IP 65 and IP 67 acc. to DIN EN 60529

Temperature Class: to T6
Ambient temperature: up to 40°C

High operating time by Hi-Power LED’s

Suits circular sight glass fittings to DIN 28120/28121 or similar from size DN 40 and screwed sight glass fittings DIN 11851 from DN 65

Operating Voltage 24 V, 120 V-230 V
Power 11 W

Secured by hinged bracket or adapter flange

Downloads

Lumistar Luminaire ASL 57LED-Ex, aluminium

Luminaires (Ex)

Product Picture: Lumistar Luminaire ASL 57LED-Ex, aluminium

ex II 2G Ex d(e) IIC T6 Gb
ex II 2D Ex tb IIIC T80°C Db

Suitable for Explosion hazardous areas

This Ex-type sight glass luminaire is designed for universal applications and is ideal for use in combined sight and light ports (single-flange version) or with two separate ports (2-flange version).

For illuminating visual flow indicators, pipelines, laboratory mixers, bio-reactors as well as the interior of tanks, hoppers, silos, agitators and other, normally closed, vessels and reactors in potentially explosive environments.

The specific advantages of Lumiglas LED technology:

  • vibration-resistant
  • long service life and operational reliability
  • LED functions up to around 50,000 hours in continuous operations
  • optimal for fittings that are difficult to access
  • no heat radiation in the light aperture (cold light)
  • no unwanted additional heat in chemical and/or biological processes
  • extremely high-contrast illumination

Compact design, powerful light output:

Glare-free illumination; suitable for circular sight glass fittings to DIN 28120/DIN 28121 or similar, for screw-type sight glass fittings in compliance with DIN 11851, from size DN 40 and for sight glass fittings on flow indicators from DN 65 .

Protection class: IP 65

Temperature Class: to T6
Ambient temperature: up to 40°C

High operating time by Hi-Power LED’s

Voltage type: AC/DC

Operating Voltage 24 V, 120 V-230 V
Power 11 W

Secured by hinged bracket or adapter flange

Downloads

Lumistar Ex Light Guide Luminaire Lumiflex Type USL 07 ALF-Ex, aluminium

Luminaires (Ex)

Product Picture: Lumistar Ex Light Guide Luminaire Lumiflex Type USL 07 ALF-Ex, aluminium

ex II 2G Ex de IIC T6/T4 Gb
ex II 2D Ex tb IIIC T80°/130°C Db

For use in Ex-hazardous areas

The Lumiglas® Series USL 07-Ex is a small, high intensity light that provides versatile illumination of process vessel interiors in locations where explosion-proof lighting is required.

For illuminating individual processes and/or the interior of reactors,  containers, apparatuses, etc. in potentially explosive environments in Zones 1 and 2 as well as Zones 21 and 22.

For mounting on sight glass fittings; particularly for the selective illumination of processes on machines and reactors with limited space, especially in potentially explosive operating areas.

This Lumiglas luminaire has been specifically developed for light guide applications:

– Economical power consumption
– Low maintenance: lamp service life of up to 6,000 hours
– Flexible light guide made of stainless steel
– Easy to clean

Protection: IP 65 and IP 67 acc. to DIN EN 60 529

Temperature class: up to T6
Ambient temperature: up to 60°C
for the localised illumination of process operations at machines and internals of reactors; Specially developed for Light guide duties
Power supply see data sheet

Please note that the halogen bulb 230 V – 75 Watt is no longer available.

Downloads

Lumistar Ex Light Guide Luminaire Lumiflex Type USL 08 ALF-Ex, aluminium

Luminaires (Ex)

Product Picture: Lumistar Ex Light Guide Luminaire Lumiflex Type USL 08 ALF-Ex, aluminium

UL-listed

For use in Explosion hazardous areas
Temperature class: T4 (60°C) & T5 (40°C)
Ignition protection: Class 1, Div.1
Explosion Group: C & D

For mounting on sight glass fittings… or for localized illumination of process operations in reactors, vessels and pipelines and also where there is limited space, primarily in potentially hazardous Ex zones.

For the illumination of process operations and/or the internals of vessels and plant in in potentially explosive environments, where the space available is limited.

The unit is made up of a general-purpose sight glass luminaire that has been modified to provide a fibre optic system which is particularly suitable for use wherever processes in Class I, Divisions 1&2, Groups C&D need to be  illuminated.

The unit can be installed for combined light and sight purposes as well as with VISULEX Ex camera technology.

This Lumistar luminaire has been specifically developed for light guide applications and is characterised by its:

Extremely high light output at only 39 W
Low energy consumption
Servicing intervals: filament lamp life greater than 6,000 hours

The light source can also be mounted at a distance from a vibrating vessel to extend the bulb life.

Protection: Suitable for wet locations acc. to UL-1598 and CSA C22.2
No. 250.0-08, IP65/IP67 (similar to NEMA4+4x), Class I, Div 1 & 2, Groups C & D

For the localised illumination of process operations at machines and internals of reactors; Specially developed for Light guide duties Power supply see data sheet

Downloads

Lumistar VISULEX Driving Luminaire Type USL 07-Ex, aluminium – USL 07-Ex Series

Luminaires (Ex)

Product Picture: Lumistar VISULEX Driving Luminaire Type USL 07-Ex, aluminium

ex II 2G Ex d(e) II C 120°C Gb
ex II 2D Ex tb IIIC T120°C Db

The Lumiglas® Series USL 07-Ex is a small, high intensity light that provides versatile illumination of process vessel interiors in locations where explosion-proof lighting is required.

It can be used in virtually any hazardous area and is suitable for food processing.

Small in size and rated EEx d IIC T3…T6 for all explosion classes, the  SL07-Ex Luminaire is as versatile as you could ever want. It can be configured for integral light/sight glasses in its single-port version, or for separate light and sight glasses in a dual-port version.

Primarily used on special vehicles operating in the industrial sector, such as fork lifters, stacker trucks, tank trucks, etc., that are mainly driven in explosion hazardous environments.

Depending on the size sight glass, it can be used with circular sight glass fitting, weld-on styles Series DIN28120 , ANSI flange bolt-on types , and with visual flow indicators .

Cenelec approved for Class IIc for Zones 1 & 2 (all explosion classes) and are dust and waterjet proof to IP 65, EN 60598 and NEMA type 4.

Housing measures only 5.5-in. long by 2.75 in. diameter.

Rated voltage: 24 V AC/DC, 50 W

Supply voltage can be 12 V, 24 V, 120 V or 230 V.

Please note that the halogen bulb 230 V – 75 Watt is no longer available.

Downloads

Lumistar VISULEX Combined Luminaire Type USL 46-Ex, aluminium

Luminaires (Ex)

Product Picture: Lumistar VISULEX Combined Luminaire Type USL 46-Ex, aluminium

ex II 2G Ex d(e) II C T3/T4/120°C
ex II 2D Ex tb IIIC T120°C/T130°C/T195°C

For stop- and rear – Light and also as Direction Indicator
Power: 24V DC

Combined brake light, rear lamp and direction indicator flasher

3. Lumistar Ex combination luminaire type USL 46-Ex

Luminaires for vehicles used in Ex category environments must not only meet all requirements on driving safety, but also need to comply with the Ex directives specified by ATEX. At the same time, they are expected to be reasonably priced.These complex demands are met by Lumistar Ex vehicle luminaires which are approved for use in potentially explosive environments:
Gas: zone 1 and 2; Dust: zone 21 and 22.

Primarily used on special vehicles operating in the industrial sector, such as fork lifters, stacker trucks, tank trucks, etc., that are mainly driven in explosion hazardous environments.

Rated voltage: 12 V, 24 V DC with 7 W LED illuminant
Certification: EC Type-Examination Certificate BVS 08 ATEX E 135

Downloads

ATEX: VISULEX Ex-Camera Type K06-Ex, aluminium

VISULEX Camera Systems (Ex)

Product Picture: ATEX: VISULEX Ex-Camera Type K06-Ex, aluminium
  • Ex II 2G Ex de IIC T6 Gb
  • Ex II 2G Ex tb IIIC T80°C Db

Camera with fixed lens. With this simple standard camera, the lens is set permanently at the time of installation so as to focus the camera on the subject (outdoor areas/outside plant or process operation).

Downloads

Similar to the internationally renowned Lumiglas luminaires, the camera system can be attached to the cover flange of a sight glass fitting using a hinged bracket. If the standard illumination of the process is not sufficient, an additional Lumiglas luminaire can be attached if fitting allows.

Application check list

Please make use of our system conformity for your application of the VISULEX-Lumiglas-camera system so that we are able to submit a correct offer fitting your specific application.